Search results for "Hand position"

showing 3 items of 3 documents

Pointing to double-step visual stimuli from a standing position: motor corrections when the speed-accuracy trade-off is unexpectedly modified in-flig…

2011

The time required to complete a fast and accurate movement is a function of its amplitude and the target size. This phenomenon refers to the well known speed-accuracy trade-off. Some interpretations have suggested that the speed-accuracy trade-off is already integrated into the movement planning phase. More specifically, pointing movements may be planned to minimize the variance of the final hand position. However, goal-directed movements can be altered at any time, if for instance, the target location is changed during execution. Thus, one possible limitation of these interpretations may be that they underestimate feedback processes. To further investigate this hypothesis we designed an ex…

AdultMaleVisual perceptionComputer sciencemedia_common.quotation_subjectMovementMotion PerceptionTrade-offHand positionExecutive FunctionYoung AdultControl theoryFeedback SensoryPerceptionOrientationReaction TimeHumansmedia_commonCommunicationbusiness.industryGeneral NeuroscienceGRASPHandAmplitudeSpeed accuracybusinessMovement planningPsychomotor PerformanceNeuroscience
researchProduct

Comparison of Different Methods for the Calculation of Indices of Paternity

1992

The qualitative decision about paternity in trio cases on the basis of DNA multilocus profiles is no problem. If there are more than 1 or 2 exclusion patterns (band present in child, which is neither present in mother or alleged father), the putative father has to be excluded. The problems arise, if, in the case of a non exclusion, one wants to quantify the evidence for paternity. Different statistics have been proposed for this purpose. This paper discusses three of these statistics and demonstrates their application to real data.

Hand positionBasis (linear algebra)StatisticsMathematics
researchProduct

Reliability of automated optical determination of capillary refill time

2021

The present study is devoted to assessment of automated optical capillary refill time determination by custom developed optoelectronic device prototype. Study comprised fifteen healthy volunteers; To induce capillary refill time changes the hand position challenge was utilized. During rest conditions slight inter-subject variation was observed: T90 (0.75±0.27 s), TSTB (2.20±0.58 s) and temperature at the measurement site (32.21±1.87 Co), however during hand position challenge results were more consistent. Rising hand substantially increased, while lowering slightly decreased capillary refill time. We conclude that automated determination of refill time have high clinical potential, however …

Hand positionTime changesLight intensitymedicine.diagnostic_testComputer scienceDecreased capillary refill timeHealthy volunteersmedicineCapillary refillMeasurement siteReliability (statistics)Biomedical engineeringBiophotonics Congress 2021
researchProduct